Main switch - Safety switch 4-p 55kW P3100EA/SVB-SWN/HI11

Eaton - P3100EA/SVB-SWN/HI11 - Main switch - Safety switch 4-p 55kW P3100EA/SVB-SWN/HI11
Photo source: fig. possibly similar
Photo source: fig. possibly similar
P3100EA/SVB-SWN/HI11 079216 4015080792161 EAN/GTIN DE 92318050 WEEE

¥1,153.18 excl. VAT
¥1,873.25 (-38.44% RRP***)

15-16 days* (CHN)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Version as main switch=yes, Version as maintenance-/service switch=yes, Version as safety... more
Main switch - Safety switch 4-p 55kW P3100EA/SVB-SWN/HI11 – Eaton – 079216 – 4015080792161: Version as main switch=yes, Version as maintenance-/service switch=yes, Version as safety switch=no, Version as emergency stop installation=no, Version as reversing switch=no, Number of switches=1, Max. rated operation voltage Ue AC=690 V, Rated operating voltage=690 V, Rated permanent current Iu=100 A, Rated permanent current at AC-23, 400 V=100 A, Rated permanent current at AC-21, 400 V=100 A, Rated operation power at AC-3, 400 V=37 kW, Rated short-time withstand current lcw=2 kA, Rated operation power at AC-23, 400 V=55 kW, Switching power at 400 V=55 kW, Conditioned rated short-circuit current Iq=4 kA, Number of poles=4, Number of auxiliary contacts as normally closed contact=1, Number of auxiliary contacts as normally open contact=1, Motor drive optional=no, Motor drive integrated=no, Voltage release optional=no, Device construction=Built-in device fixed built-in technique, Suitable for floor mounting=no, Suitable for front mounting 4-hole=yes, Suitable for front mounting centre=no, Suitable for distribution board installation=no, Suitable for intermediate mounting=no, Colour control element=Black, Type of control element=Door coupling rotary drive, Interlockable=yes, Type of electrical connection of main circuit=Screw connection, Degree of protection (IP), front side=IP65, Degree of protection (NEMA)=12
... more
Version as main switch yes
Version as maintenance / repair switch yes
Version as safety switch no
Version as emergency stop device no
Version as reversing switch no
Number of switches 1
Max. Rated operating voltage Ue at AC 690V
Rated operating voltage 690V
Rated continuous current Iu 100 A
Rated uninterrupted current at AC-23, 400 V 100 A
Rated continuous current at AC-21, 400 V 100 A
Rated operating power at AC-3, 400V 37 kW
Rated short-time withstand current Icw 2 kA
Rated operating power at AC-23, 400V 55 kW
Switching capacity at 400 V 55 kW
Conditional rated short-circuit current Iq 80 kA
Number of poles 4
Number of auxiliary contacts as NC contact 1
Number of auxiliary contacts as normally open 1
Motor drive optional no
Motor drive integrated no
Shunt release optional no
Device construction Built-in device fixed-mounted design
Suitable for ground mounting no
Suitable for front mounting 4-hole yes
Suitable for front mounting central no
Suitable for distributor installation no
Suitable for intermediate construction no
Color of the actuator black
Lockable yes
Connection type main circuit Screw
Degree of protection (IP), front side IP65
Protection class (NEMA) 12