Contactor 75KW/400V,AC DILM150-22 (RAC240) - Magnet contactor 150A 190...240VAC 0VDC DILM150-22(R...

Front view - Eaton - DILM150-22(RAC240) - Contactor 75KW/400V,AC DILM150-22 (RAC240) - Magnet contactor 150A 190...240VAC 0VDC DILM150-22(R...
View on the left - Eaton - DILM150-22(RAC240) - Contactor 75KW/400V,AC DILM150-22 (RAC240) - Magnet contactor 150A 190...240VAC 0VDC DILM150-22(R...
View on the right - Eaton - DILM150-22(RAC240) - Contactor 75KW/400V,AC DILM150-22 (RAC240) - Magnet contactor 150A 190...240VAC 0VDC DILM150-22(R...
Rear view - Eaton - DILM150-22(RAC240) - Contactor 75KW/400V,AC DILM150-22 (RAC240) - Magnet contactor 150A 190...240VAC 0VDC DILM150-22(R...
View up front - Eaton - DILM150-22(RAC240) - Contactor 75KW/400V,AC DILM150-22 (RAC240) - Magnet contactor 150A 190...240VAC 0VDC DILM150-22(R...
View top left - Eaton - DILM150-22(RAC240) - Contactor 75KW/400V,AC DILM150-22 (RAC240) - Magnet contactor 150A 190...240VAC 0VDC DILM150-22(R...
View top right - Eaton - DILM150-22(RAC240) - Contactor 75KW/400V,AC DILM150-22 (RAC240) - Magnet contactor 150A 190...240VAC 0VDC DILM150-22(R...
Top rear view - Eaton - DILM150-22(RAC240) - Contactor 75KW/400V,AC DILM150-22 (RAC240) - Magnet contactor 150A 190...240VAC 0VDC DILM150-22(R...
Photo source: fig. possibly similar
Photo source: fig. possibly similar
DILM150-22(RAC240) 239598 4015082395988 EAN/GTIN DE 92318050 WEEE

Our best price
¥4,319.32 excl. VAT
¥6,899.40 (-37.4% RRP***)

4-5 days* (CHN)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Power contactor 75KW/400V,AC DILM150-22(RAC240) rated control supply voltage Us at AC 50 Hz 190... more
Contactor 75KW/400V,AC DILM150-22 (RAC240) - Magnet contactor 150A 190...240VAC 0VDC DILM150-22(R... – Eaton – 239598 – 4015082395988: Power contactor 75KW/400V,AC DILM150-22(RAC240) rated control supply voltage Us at AC 50 Hz 190 ... 240V, rated control supply voltage Us at AC 60 Hz 190 ... 240V, rated control supply voltage Us at DC 0V, type of voltage for actuation AC, rated operational current Ie at AC-1, 400 V 190A, rated operational current Ie at AC-3, 400 V 150A, rated operational power at AC-3, 400 V 75kW, rated operational current Ie at AC-4, 400 V 65A, rated operational power at AC-4, 400 V 33kW, Rated operational power NEMA 93kW, number of auxiliary contacts as NO contact 2, number of auxiliary contacts as NC contact 2, connection type main circuit screw connection, number of NC contacts as main contacts 0, number of NO contacts as main contacts 3, power contactor, application: power contactor for motors, complete devices up to 170 A, utilization category : AC-1: Non-inductive or slightly inductive load, resistance furnaces, AC-3: Squirrel-cage motors: Starting, turning off during run, AC-4: Squirrel-cage motors re: starting, counter-current braking, reversing, jogging, connection technology: screw terminals, Note: also suitable for motors of efficiency class IE3., IE3-capable devices are marked with the logo on the packaging., Rated operational current AC-3 380 V 400 V: Ie= 150 A, rated operational current AC-1 conventional thermal current, 3-pole, 50 - 60 Hz open at 40 °C: Ith = Ie= 190 A, encapsulated: Ith= 144 A, rated operational current AC-1 conventional thermal current 1-pole open : Ith= 400 A, encapsulated: Ith= 360 A, max. rated operational power of three-phase motors 50 - 60 Hz AC-3 220 V 230 V: P= 48 kW, 380 V 400 V: P= 75 kW, 660 V 690 V: P = 96 kW, max. rated operational power of three-phase motors 50 - 60 Hz AC-4 220 V 230 V: P= 20 kW, 380 V 400 V: P= 33 kW, 660 V 690 V: P= 48 kW, contact configuration S = normally open: 2 NO, Contacts NC = NC: 2 NC, Notes: Switching elements according to EN 50012., Integrated protective circuit in the control electronics., With mirror contact., Type of current AC /DC: AC operation
... more
Rated control supply voltage Us at DC 0 V
Voltage type for actuation AC
Rated operational current Ie at AC-1, 400V 190 A
Rated operational current Ie at AC-3, 400 V 150 A
Rated operating power at AC-3, 400V 75 kW
Rated operational current Ie at AC-4, 400V 65 A
Rated operational power at AC-4, 400 V 33 kW
Rated operating power NEMA 93 kW
Suitable for serial installation no
Number of auxiliary contacts as normally open 2
Number of auxiliary contacts as NC contact 2
Connection type main circuit Screw
Number of make contacts as main contacts 3

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "Contactor 75KW/400V,AC DILM150-22 (RAC240) - Magnet contactor 150A 190...240VAC 0VDC DILM150-22(R..."
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.