RCBO 16A B 30mA A - Earth leakage circuit breaker B16/0,03A A9D07616

A9D07616 3606480484308 EAN/GTIN DE 33842582 WEEE

Our best price
¥348.09 excl. VAT
¥1,360.53 (-74.42% RRP***)

4-5 days* (CHN)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
RCBO 16A B 30mA A A9D07616, number of poles (total)=2, number of fused poles=1, rated voltage=230... more
RCBO 16A B 30mA A - Earth leakage circuit breaker B16/0,03A A9D07616 – Schneider Electric – 3606480484308: RCBO 16A B 30mA A A9D07616, number of poles (total)=2, number of fused poles=1, rated voltage=230 V, rated insulation voltage Ui=400 V, rated impulse withstand voltage Uimp=4 kV, rated current=16 A, rated residual current=0 .03 A, residual current type=A, energy limitation class=3, rated breaking capacity according to IEC 60947-2=10 kA, cut-off characteristic=other, surge current strength=0.25 kA, type of voltage=AC, frequency=50 Hz, tripping characteristic=B, switching neutral conductor =yes, with locking device=no, overvoltage category=3, degree of pollution=3, ambient temperature during operation=25..60 °C, width in modular units=2, installation depth=44 mm, suitable for flush-mounted installation=no, protection against false tripping=no , Degree of protection (IP)=IP20, Connectable conductor cross-section, solid=1..16 mm², Connectable conductor cross-section, stranded=1..10 mm², Residual current circuit breaker with overcurrent protection (FI/LS) Acti 9 iDPN H Vigi, 10kA (IEC/EN 61009). 1-pole+N, rated current 16A, B characteristic, ground fault sensitivity 30mA, ground fault protection class type A, operating voltage (Ue) 230V AC, insulation voltage (Ui) 400V AC. Ensures comprehensive protection of final circuits against overcurrents and residual currents. Switching and disconnecting circuits. Snap action for low-wear switching of the contacts. Mechanically isolated red indicator in the event of a fault tripping of the circuit breaker or tripping due to a residual current. Green marking on the switch knob of the device clearly indicates the switch position. Test button for regular function testing. Technology of trip unit - thermomagnetic. Additional add-on auxiliary modules (optional) - undervoltage release (iMN), overvoltage release (iMSU), shunt release (iMX), auxiliary switch for status reporting (iOF), fault signaling switch (iSD). Tool-free assembly on the left side of the device. Color RAL 9003. The RCD IDPN H Vigi complies with the following standards - IEC/EN 61009 and IEC/EN 60947-2. Furthermore, this series is VDE certified!
... more
Number of poles (total) 2
Number of secured poles 1
Rated voltage 230V
Rated insulation voltage Ui 400V
Rated impulse withstand voltage Uimp 4 kV
Rated current 16 A
Rated fault current 0.03 A
Fault current type A
Limiting class 3
Rated breaking capacity according to EN 61009 10 kA
turn-off characteristic instantaneously
Surge current resistance 0.25 kA
Voltage AC
Frequency 50 Hz
Release characteristic B
Coupling neutral conductor yes
With locking device no
Overvoltage category 3
Pollution degree 3
Width in division units 2
Depth 44 mm
Flush mounting no
False triggering protection no
IP protection) IP20