Monitoring relay - Effective power relay AC230V CPW-E12 230AC1W 10A

CPW-E12 230AC1W 10A 1102810520 4250184121039 EAN/GTIN DE 87494433 WEEE

Our best price
¥483.57 excl. VAT
¥1,024.39 (-52.79% RRP***)

15-16 days* (CHN)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Monitoring relay CPW-E12 230AC1W 10A rated control supply voltage Us at AC 50 Hz 230 ... 230V,... more
Monitoring relay - Effective power relay AC230V CPW-E12 230AC1W 10A – Metz – 1102810520 – 4250184121039: Monitoring relay CPW-E12 230AC1W 10A rated control supply voltage Us at AC 50 Hz 230 ... 230V, rated control supply voltage Us at AC 60 Hz 230 ... 230V, rated voltage 230 ... 400V, measuring current 1 ... 10A, rated operating frequency 2 ... 200Hz , Number of phases 3, Adjustable response value for Cos-Phi 0 ... 0.97, Min. adjustable response delay time 1s, Max. permissible response delay time 100s, Min. adjustable off-delay time 1s, Max. permissible off-delay time 100s, Number of contacts as normally closed contacts 0 , Number of contacts as normally open 0, Number of contacts as changeover 1, width 22.5mm, height 75mm, depth 100mm, The cosPhi monitor is used to detect underload. The response value and response time are adjustable. It can also be used in conjunction with a frequency converter (frequency 2 to 200 Hz). Monitoring is carried out by detecting the phase shift between current and voltage. This phase angle shifts with the load on a motor. Settings of the functions via bridges S1 - S2 - S3S1 - S2 open = with underload relay dropped out S1 - S2 bridged = with underload relay energized S1 - S3 open = with error memory S1 - S3 bridged = without error memory. The module can be unlocked remotely via a closer on S1 - S3. With the error memory (no bridge over S1-S3), the error message remains until acknowledged or until the supply voltage is interrupted.
... more
With removable clamps no
Voltage type for actuation AC
Number of contacts as changer 1
Width 22.5 mm
Height 75 mm
Depth 95 mm