Combined arrester for power systems SPA701Z

SPA701Z 3250615514998 EAN/GTIN DE 23692311 WEEE

Our best price
¥1,967.56 excl. VAT
¥3,713.39 (-47.01% RRP***)

4-5 days* (CHN)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Combined arrester for power systems System configuration TN-S, Number of poles 4, Lightning... more
Combined arrester for power systems SPA701Z – Hager – 3250615514998: Combined arrester for power systems System configuration TN-S, Number of poles 4, Lightning impulse current (10/350 µs) 7,5kA, Max. continuous voltage AC 255V, Nominal voltage AC 400V, Max. PV-voltage 0V, Voltage protection level 1,5kV, Voltage protection level L-N 1,5kV, Voltage protection level L-PE 1,5kV, Voltage protection level N-PE 1,5kV, Follow current extinguishing capability 25kA, Max. conductor cross section solid (solid, stranded) 50mm², Max. conductor cross section flexible (fine-strand) 35mm², Mounting method Busbar, Construction size Other, Signalling at the device Optic, Test class Type 1 + 2, Degree of protection (IP) IP20
... more
Network form DC no
Network form IT no
Network shape TN no
Mains form TN-C no
Mains form TN-CS no
Mains form TN-S yes
Network shape TT yes
Network form other no
Number of poles 4
Lightning impulse current (10/350 µs) 7.5 kA
Highest continuous voltage AC 255V
Rated voltage AC 400V
Max. PV voltage 0 V
Protection level 1.5 kV
Protection level LN 1.5 kV
Protection level L-PE 1.5 kV
Protection level N-PE 1.5 kV
Follow current extinguishing capability 25 kA
Specific energy (W / R) 376,5 mm
Mounting Bus bar
Size other
Remote signaling no
Signaling on the device optical
Test class Type 1 and 2 and 3
Integrated backup fuse no
Voltage switching spark gap technology yes
IP protection) IP20