Arc fault protection AFDD with LS 1P+N 10kA - Miniature circuit breaker 2-p B16A ARC516D

Hager - ARC516D - Arc fault protection AFDD with LS 1P+N 10kA - Miniature circuit breaker 2-p B16A ARC516D
Photo source: fig. possibly similar
Photo source: fig. possibly similar
ARC516D 3250611019893 EAN/GTIN DE 23692311 WEEE

Our best price
¥1,039.98 excl. VAT
¥1,805.43 (-42.4% RRP***)

15-16 days* (CHN)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Arc fault protection AFDD m.LS 1P+N 10kA ARC516D tripping characteristic B, number of poles 2,... more
Arc fault protection AFDD with LS 1P+N 10kA - Miniature circuit breaker 2-p B16A ARC516D – Hager – 3250611019893: Arc fault protection AFDD m.LS 1P+N 10kA ARC516D tripping characteristic B, number of poles 2, rated current 16A, rated voltage 230V, rated breaking capacity according to EN 61009 10kA, type of voltage AC, energy limitation class 3, frequency 50Hz, switching neutral conductor, overvoltage category 3, degree of pollution 2, size ( according to DIN 43880) 1, width in modular units 2, installation depth 70mm, additional devices installed at the factory AFD unit, degree of protection (IP) IP20, arc fault protection device AFDD with circuit breaker 1P+N 10kA B-16A 2M. AFDD fire protection switch according to DIN EN 62606 (VDE 0665-10), combined with circuit breaker 1P+N, with electronic differential current measurement (300 mA) to increase fire protection in circuits not protected with RCD, with screw technology. Contact protection according to IP2x DIN VDE 0106 part 100, blue test button and AFD tripped display. Easy individual removal from the phase busbar assembly. With VDE mark. Suitable for retrofitting additional equipment. Labeling option directly on the device.
... more
Release characteristic B
Number of poles 2
Rated current 16 A
Rated voltage 230V
Rated breaking capacity according to EN 60898 10 kA
Voltage AC
Limiting class 3
Frequency 50 Hz
Coupling neutral conductor yes
Overvoltage category 3
Pollution degree 2
Width in division units 2
Depth 70 mm
IP protection) IP20
Size (according to DIN 43880) 1