Type 1 coordinated lightning arrester - Lightning arrest for power supply 25kA 971120

Dehn - 971120 - Type 1 coordinated lightning arrester - Lightning arrest for power supply 25kA 971120
Photo source: fig. possibly similar
Photo source: fig. possibly similar
971120 4013364133631 EAN/GTIN DE 11890845 WEEE

¥1,498.56 excl. VAT
¥2,987.59 (-49.84% RRP***)

15-16 days* (CHN)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Coordinated lightning current arrester type 1 971120 DC network type, number of conductors... more
Type 1 coordinated lightning arrester - Lightning arrest for power supply 25kA 971120 – Dehn – 4013364133631: Coordinated lightning current arrester type 1 971120 DC network type, number of conductors (without earth) 1, lightning impulse current (10/350 µs) 25kA, maximum continuous voltage DC 220V, protection level 2.5kV, specific energy (W/R) 156.25kJ/Ohm, mounting type Top-hat rail TH35, size 2 HP, Max. conductor cross-section, rigid (solid/stranded) 50mm², Max. conductor cross-section, flexible (finely stranded) 35mm², Visual signaling on the device, Test class type 1, Degree of protection (IP) IP20, Single-pole, coordinated DEHNsecure lightning current arrester modular, Classification Type 1 according to EN 61643-11 based on spark gaps. Spark gap technology especially suitable for use in DC circuits. To protect DC consumer systems against overvoltages, even in the event of direct lightning strikes. For use in the lightning protection zone concept at the interfaces 0A - 1.
... more
Network form DC yes
Network form IT no
Network shape TN no
Mains form TN-C no
Mains form TN-CS no
Mains form TN-S no
Network shape TT no
Network form other no
Number of conductors (without earth) 1
Lightning impulse current (10/350 µs) 25 kA
Highest continuous voltage DC 220V
Protection level 2.5 kV
Specific energy (W / R) 156.25 kJ/ohms
Mounting DIN rail TH35
Size 2 TE
With telecommunication contact no
Blow out no
Signaling on the device optical
Test class type 1 yes
Integrated backup fuse no
Suitable for outdoor use no
IP protection) IP20