RCD combination 6kA,4P,type AC13A,30mA - Distributor assembly with RCBO 13/30mA DS204 A-C13/0,03

ABB - DS204 A-C13/0,03 - RCD combination 6kA,4P,type AC13A,30mA - Distributor assembly with RCBO 13/30mA DS204 A-C13/0,03
Photo source: fig. possibly similar
Photo source: fig. possibly similar
DS204 A-C13/0,03 2CSR254101R1134 8012542862703 EAN/GTIN DE 91945327 WEEE

¥1,409.13 excl. VAT
¥2,423.68 (-41.86% RRP***)

15-16 days* (CHN)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
FI/LS combination 6kA,4P,TypAC13A,30mA DS204 A-C13/0.03 Version as main switch, Version as... more
RCD combination 6kA,4P,type AC13A,30mA - Distributor assembly with RCBO 13/30mA DS204 A-C13/0,03 – ABB – 2CSR254101R1134 – 8012542862703: FI/LS combination 6kA,4P,TypAC13A,30mA DS204 A-C13/0.03 Version as main switch, Version as maintenance/repair switch, Max. rated operating voltage Ue at AC 1000V, Rated operating voltage 1000... 1000V, Rated continuous current Iu 160A, Rated continuous current at AC-23, 400 V 160A, Rated continuous current at AC-21, 400 V 200A, Rated operational power at AC-3, 400 V 80kW, Rated short-time withstand current Icw 8kA, Rated operational power at AC-23, 400 V 88kW, Switching power at 400 V 160kW, Number of poles 4, number of auxiliary contacts as normally closed contacts 0, number of auxiliary contacts as normally open contacts 0, number of auxiliary contacts as changeover contacts 0, suitable for floor mounting, suitable for front mounting 4-hole, suitable for distribution board installation, lockable, offer FI/LS combinations (RCBOs). Protection of people and property as well as protection against electrically ignited fires in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. They ensure protection of 1P+N, 2P, 3P+N or 4P circuits against overload and short-circuit currents, protection against sinusoidal alternating currents and pulsating currents with smooth DC residual current of up to 6 mA to earth. As well as fault protection (protection against indirect contact), additional protection (with In <= 30 mA) and fire protection (with In <= 300 mA). They meet the product standard IEC/EN 61009-1 (VDE 0664-20). Areas of application include household, commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the DS200 fit for worldwide use. Rated switching capacity Icn = 6,000 A according to IEC/EN 61009-1 (VDE 0664-20) for RCDs (residual current protective devices) in residential buildings and similar applications, Icu = 10 kA according to IEC/EN 60947-2 (VDE 0660-101) for MCBs (LS) in industrial applications. RCBO DS200 Type A is 2/4-pole protected (LS), 2-/4-pole switching.
... more
Rated current 13 A
Rated fault current 30 mA
Number of secured poles 4
Coupling neutral conductor no
Release characteristic C
Breaking 6 kA
Wiring on terminal block no
Height 93 mm
Width 105 mm
Depth 69 mm