RCCB type B 4P 63A,300mA,3kA,4TE - Residual current breaker 4-p F204B-63/0,3-4TE

ABB - F204B-63/0,3-4TE - RCCB type B 4P 63A,300mA,3kA,4TE - Residual current breaker 4-p F204B-63/0,3-4TE
Photo source: fig. possibly similar
Photo source: fig. possibly similar
F204B-63/0,3-4TE 2CSF204568R3630 8012542342458 EAN/GTIN DE 91945327 WEEE

Our best price
¥3,426.19 excl. VAT
¥10,472.43 (-67.28% RRP***)

4-5 days* (CHN)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Residual current breaker 4-p Number of poles 4, Rated voltage 400V, Rated current 63A, Rated... more
RCCB type B 4P 63A,300mA,3kA,4TE - Residual current breaker 4-p F204B-63/0,3-4TE – ABB – 2CSF204568R3630 – 8012542342458: Residual current breaker 4-p Number of poles 4, Rated voltage 400V, Rated current 63A, Rated insulation voltage Ui 440V, Rated impulse withstand voltage Uimp 4kV, Mounting method DIN rail, Leakage current type B, Frequency 50/60 Hz, Additional equipment possible, Degree of protection (IP) IP20, Width in number of modular spacings 4, Built-in depth 69,5mm, Ambient temperature during operating -25 ... 70°C, Pollution degree 3, Connectable conductor cross section solid-core 1 ... 25mm²
... more
Number of poles 4
Rated voltage 400V
Rated current 63 A
Rated fault current 0.3 A
Rated insulation voltage Ui 440V
Rated impulse withstand voltage Uimp 4 kV
Mounting DIN rail
Fault current type B
Selective type no
Short time delayed type no
Surge current resistance 3 kA
Voltage AC
With locking device no
Frequency other
Additional equipment possible yes
IP protection) IPX4
Width in division units 4
Depth 69.5 mm
Pollution degree 3
Explosion protection no