RCCB type B 4P 40A,30mA,3kA,4TE - Residual current breaker 4-p F204B-40/0,03-4TE

F204B-40/0,03-4TE 2CSF204568R1400 8012542342052 EAN/GTIN DE 91945327 WEEE

Our best price
¥2,704.26 excl. VAT
¥8,429.62 (-67.92% RRP***)

4-5 days* (CHN)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Number of poles 4, Rated voltage 400V, Rated current 40 A, Rated fault current 0.03 A, Rated... more
RCCB type B 4P 40A,30mA,3kA,4TE - Residual current breaker 4-p F204B-40/0,03-4TE – ABB – 2CSF204568R1400 – 8012542342052: Number of poles 4, Rated voltage 400V, Rated current 40 A, Rated fault current 0.03 A, Rated insulation voltage Ui 440V, Rated impulse withstand voltage Uimp 4 kV, Mounting DIN rail, Fault current type B, Selective type no, Short time delayed type no, Short-circuit strength (Icw) 10 kA, Surge current resistance 3 kA, Voltage AC, With locking device no, Frequency 50/60 Hz, Additional equipment possible yes, IP protection) IP20, Width in division units 4, Depth 69.5 mm, Pollution degree 3, Explosion protection no
... more
Number of poles 4
Rated voltage 400V
Rated current 40 A
Rated fault current 0.03 A
Rated insulation voltage Ui 440V
Rated impulse withstand voltage Uimp 4 kV
Mounting DIN rail
Fault current type B
Selective type no
Short time delayed type no
Short-circuit strength (Icw) 10 kA
Surge current resistance 3 kA
Voltage AC
With locking device no
Frequency other
Additional equipment possible yes
IP protection) IPX4
Width in division units 4
Depth 69.5 mm
Pollution degree 3
Explosion protection no

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "RCCB type B 4P 40A,30mA,3kA,4TE - Residual current breaker 4-p F204B-40/0,03-4TE"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.