Single-channel level monitor - Level relay conductive sensor MS91-12-R

Turck - MS91-12-R - Single-channel level monitor - Level relay conductive sensor MS91-12-R
Photo source: fig. possibly similar
Photo source: fig. possibly similar
MS91-12-R 5220110 4047101105476 EAN/GTIN DE 71889523 WEEE

Our best price
¥2,334.40 excl. VAT

15-16 days* (CHN)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Single-channel level monitor MS91-12-R Design of the electrical connection screw connection,... more
Single-channel level monitor - Level relay conductive sensor MS91-12-R – Turck – 5220110 – 4047101105476: Single-channel level monitor MS91-12-R Design of the electrical connection screw connection, rated control supply voltage Us at AC 50 Hz 20 ... 250V, rated control supply voltage Us at AC 60 Hz 20 ... 250V, rated control supply voltage Us at DC 20 ... 250V, type of voltage for actuation AC/DC, number of electrode inputs 3, min. adjustable on-delay time 0.1s, max. permissible on-delay time 15s, min. adjustable off-delay time 0.1s, max. permissible off-delay time 15s, response sensitivity adjustable, number of contacts as break contacts 0, number of contacts as NO contact 0, number of contacts as changeover contact 2, physical measuring principle conductive, width 50mm, height 75mm, depth 110mm, level monitor, 1-channel, output: two relays with changeover switch, response sensitivity: 0.2-100 kOhm, removable terminal blocks, electrode changeover via built-in auxiliary relay, switch-on and switch-off delay 0.1-15 s adjustable, reliable differentiation from liquids and foam, galvanic isolation of input circuits from output circuits and supply voltage
... more
Voltage type for actuation AC/DC
With removable clamps no
Number of electrode inputs 3
Minimum adjustable pick-up delay time 0.1 s
Max. Permissible pick-up delay time 15 s
Max. Allowable fallback delay time 15 s
Sensitivity adjustable yes
Number of contacts as changer 2
Physical measuring principle conductive
Width 50 mm
Height 75 mm
Depth 110 mm