Transformer 1 phase 0.8/3.4 Upri=600-2 - One-phase transformer 600V/230V 800VA 4AM5542-8ED40-0FA0

Siemens - 4AM5542-8ED40-0FA0 - Transformer 1 phase 0.8/3.4 Upri=600-2 - One-phase transformer 600V/230V 800VA 4AM5542-8ED40-0FA0
Photo source: fig. possibly similar
Photo source: fig. possibly similar
4AM5542-8ED40-0FA0 4001869905235 EAN/GTIN DE 23691322 WEEE

¥3,115.39 excl. VAT

15-16 days* (CHN)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Built as safety transformer=no, Built as isolating transformer=no, Built as energy saving... more
Transformer 1 phase 0.8/3.4 Upri=600-2 - One-phase transformer 600V/230V 800VA 4AM5542-8ED40-0FA0 – Siemens – 4001869905235: Built as safety transformer=no, Built as isolating transformer=no, Built as energy saving transformer=no, Primary voltage 1=600 V, Primary voltage 2=575 V, Primary voltage 3=550 V, Primary voltage 4=525 V, Primary voltage 5=500 V, Primary voltage 6=480 V, Primary voltage 7=460 V, Primary voltage 8=440 V, Primary voltage 9=415 V, Primary voltage 10=400 V, Secondary voltage 1=230 V, Secondary voltage 2=115 V, Secondary voltage 6=0 V, Secondary voltage 7=0 V, Secondary voltage 8=0 V, Secondary voltage 9=0 V, Secondary voltage 10=0 V, Rated apparent power=800 VA, Type of insulation material according to IEC 85=B, Short-circuit-proof=no, Relative short circuit voltage=3,1 %, Width=152 mm, Height=144 mm, Depth=126 mm, Degree of protection (IP)=IP00, Ring core=no, Suitable for mounting on PCB=no, Modular version=no, Conductor material=Other
... more
Executed as a safety transformer no
Executed as a separation transformer no
Engineered as a savings transformer no
Primary voltage 1 600V
Primary voltage 2 575 V
Primary voltage 3 550V
Primary voltage 4 525 V
Primary voltage 5 500V
Primary voltage 6 480V
Primary voltage 7 460V
Primary voltage 8 440V
Primary voltage 9 415 V
Primary voltage 10 400V
Secondary voltage 1 230V
Secondary voltage 2 115 V
Rated power 800 VA
Insulation class according to IEC 85 B
Short circuit protection no
Relative short-circuit voltage uk 3.1%
Conductor material other
Width 152 mm
Height 144 mm
Depth 126 mm
IP protection) IP00