Transformer 1 phase 0.63/2.35 Upri=550 - One-phase transformer 550V/24V 630VA 4AM5242-8DN00-0EA0

Siemens - 4AM5242-8DN00-0EA0 - Transformer 1 phase 0.63/2.35 Upri=550 - One-phase transformer 550V/24V 630VA 4AM5242-8DN00-0EA0
Photo source: fig. possibly similar
Photo source: fig. possibly similar
4AM5242-8DN00-0EA0 4001869904696 EAN/GTIN DE 23691322 WEEE

¥2,604.58 excl. VAT

15-16 days* (CHN)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Built as safety transformer=no, Built as isolating transformer=no, Built as energy saving... more
Transformer 1 phase 0.63/2.35 Upri=550 - One-phase transformer 550V/24V 630VA 4AM5242-8DN00-0EA0 – Siemens – 4001869904696: Built as safety transformer=no, Built as isolating transformer=no, Built as energy saving transformer=no, Primary voltage 1=550 V, Primary voltage 2=525 V, Primary voltage 3=500 V, Primary voltage 4=480 V, Primary voltage 5=460 V, Primary voltage 6=440 V, Primary voltage 7=415 V, Primary voltage 8=400 V, Primary voltage 9=380 V, Primary voltage 10=230 V, Secondary voltage 1=24 V, Secondary voltage 6=0 V, Secondary voltage 7=0 V, Secondary voltage 8=0 V, Secondary voltage 9=0 V, Secondary voltage 10=0 V, Rated apparent power=630 VA, Type of insulation material according to IEC 85=B, Short-circuit-proof=no, Relative short circuit voltage=3,7 %, Width=152 mm, Height=144 mm, Depth=110 mm, Degree of protection (IP)=IP00, Ring core=no, Suitable for mounting on PCB=no, Modular version=no, Conductor material=Other
... more
Executed as a safety transformer no
Executed as a separation transformer no
Engineered as a savings transformer no
Primary voltage 1 550V
Primary voltage 2 525 V
Primary voltage 3 500V
Primary voltage 4 480V
Primary voltage 5 460V
Primary voltage 6 440V
Primary voltage 7 415 V
Primary voltage 8 400V
Primary voltage 9 380V
Primary voltage 10 230V
Secondary voltage 1 24V
Secondary voltage 6 0 V
Secondary voltage 7 0 V
Secondary voltage 8 0 V
Secondary voltage 9 0 V
Secondary voltage 10 0 V
Rated apparent power 630 VA
Insulation class according to IEC 85 B
Short circuit protection no
Relative short-circuit voltage uk 3.7%
Width 152 mm
Height 144 mm
Depth 110 mm
IP protection) IP00
Toroidal no
Suitable for PCB mounting no
Suitable for serial installation no
Conductor material other

Rate item

(0 reviews)