RCBO compact type A(G), 30mA, C6 - Earth leakage circuit breaker C6/0,03A 5SV1316-7LK06

Siemens - 5SV1316-7LK06 - RCBO compact type A(G), 30mA, C6 - Earth leakage circuit breaker C6/0,03A 5SV1316-7LK06
Photo source: fig. possibly similar
Photo source: fig. possibly similar
5SV1316-7LK06 4001869558080 EAN/GTIN DE 23691322 WEEE

¥670.24 excl. VAT
¥1,199.87 (-44.14% RRP***)

15-16 days* (CHN)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
RCBO compact type A(G), 30mA, C6 5SV1316-7LK06 number of poles (total) 2, number of fused poles... more
RCBO compact type A(G), 30mA, C6 - Earth leakage circuit breaker C6/0,03A 5SV1316-7LK06 – Siemens – 4001869558080: RCBO compact type A(G), 30mA, C6 5SV1316-7LK06 number of poles (total) 2, number of fused poles 1, rated voltage 230V, rated insulation voltage Ui 253V, rated impulse withstand voltage Uimp 4kV, rated current 6A, rated residual current 0.03A, residual current -Type A, energy limitation class 3, rated breaking capacity according to EN 61009 6kA, rated breaking capacity according to IEC 60947-2 10kA, rated short-circuit breaking capacity Icn according to EN 61009-1 6kA, short-time delayed switch-off characteristic, surge current strength 3kA, type of voltage AC, tripping characteristic C, switching neutral conductor, with locking device, overvoltage category 3 , Degree of pollution 2, Ambient temperature during operation -25 ... 45°C, Width in pitch units 1, Installation depth 70mm, Suitable for flush-mounted installation, False tripping protection, Degree of protection (IP) IP20, Connectable conductor cross-section solid 0.75 ... 16mm², Connectable conductor cross-section stranded 0.75 ... 16mm², FI/LS kom pakt 1P+N 6kA Type A(G) 30mA C6 The FI switch is the residual current protective device for contact protection The patented residual current protective devices from Siemens are an important part of the SENTRON protective components for the electrical installation, because they prevent life-threatening electrical accidents by safely switching off dangerous fault currents to earth. Electrically ignited fires can be prevented as soon as they start. Whether by directly touching live parts during operation or by indirectly touching equipment - the protection is primarily achieved by switching off quickly. The main features of the Siemens 5SV RCCBs are: 1. Comprehensive protection for people and property against electric shock. 2. Whether sinusoidal AC residual currents or smooth DC residual currents - Siemens offers the right type and special versions for all requirements. 3. Reliable safety during installation thanks to the grip and touch protection included as standard. 4. Tool-free removal from the top-hat rail or from the busbar assembly through convenient slide-hand operation. 5. Data matrix code on the front of the device provides all information about the residual current circuit breaker quickly and easily. 6. Be protected according to standards: The residual current circuit breakers comply with the provisions of DIN VDE. 7. Optimum technology for your safety - only from Siemens. For the safe, efficient electrical infrastructure in buildings and industry, Siemens offers a comprehensive portfolio of protective switching, measuring and monitoring devices, distribution systems, switches and socket outlets.
... more
Number of poles (total) 2
Number of secured poles 1
Rated voltage 230V
Rated insulation voltage Ui 253 V
Rated impulse withstand voltage Uimp 4 kV
Rated current 6A
Rated fault current 0.03 A
Fault current type A
Limiting class 3
Rated breaking capacity according to EN 61009 6 kA
turn-off characteristic time-delayed
Surge current resistance 3 kA
Voltage AC
Frequency 50 Hz
Release characteristic C
Coupling neutral conductor yes
With locking device yes
Overvoltage category 2
Pollution degree 2
Width in division units 1
Depth 70 mm
Flush mounting yes
False triggering protection yes
IP protection) IP20

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "RCBO compact type A(G), 30mA, C6 - Earth leakage circuit breaker C6/0,03A 5SV1316-7LK06"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.