Pushbutton input module for RS485 bus FTS14EM

FTS14EM 30014060 4010312315071 EAN/GTIN DE 30298319 WEEE

Our best price
¥384.00 excl. VAT
¥553.86 (-30.67% RRP***)

4-5 days* (CHN)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Button input module for RS485 bus FTS14EM bus system radio bus, other bus systems other, radio... more
Pushbutton input module for RS485 bus FTS14EM – Eltako – 30014060 – 4010312315071: Button input module for RS485 bus FTS14EM bus system radio bus, other bus systems other, radio bidirectional, mounting type REG, width in division units 2, number of actuation points 10, mounting type clamp mounting, protection class (IP) IP20, input module for the Eltako RS485 bus, 10 control inputs for universal control voltage. Stand-by loss only 0.1 watts. Series installation device for mounting on DIN-EN 60715 TH35 mounting rail. 2 division units = 36mm wide, 58mm deep. Connection to the Eltako RS485 bus. Cross-wiring bus and power supply with jumpers. Operation in conjunction with FAM14 or FTS14KS. 10 control inputs +E1..+E10/-E galvanically isolated from the supply voltage. Control voltage: 8..230V UC. The control inputs can be activated either for buttons (as delivered), window/door contacts or motion detectors. From production week 21/19, the signals of the control inputs can be inverted. Control inputs for buttons: Telegrams are generated by radio buttons (e.g. 0x70). Each FTS14EM can be set to either UT (= universal button) or RT (= direction button) using the lower rotary switch. Control inputs for window-door contacts: Telegrams from the wireless window-door contact FTK are generated (EEP D5-00-01). If the input is controlled by the contact with the control voltage to be applied externally, the window closed telegram is generated. When the contact is opened, the telegram window is created open. As with the FTK wireless sensors, the status telegram is repeated every 15 minutes. Control inputs for motion detectors: Telegrams from the radio motion brightness sensor FBH are generated (EEP A5-08-01), whereby the brightness value is always 0. If the input is controlled by the contact with the externally applied control voltage, the movement telegram is generated. When the contact is opened, the No movement telegram is generated. As with the FBH wireless sensors, the status telegram is repeated every 15 minutes. Each telegram of a contact input must be taught in with an identification number (ID) in one or more actuators in accordance with their operating instructions. The lower rotary switch determines which group an FTS14EM belongs to. A total of 5 groups (1, 101, 201, 301, and 401) with 100 IDs each are available. The ID within a group is set at the top rotary switch (0..90). The ID range within a group results from the combination of the lower and upper rotary switches and must be set differently on each FTS14EM. A maximum of 10 FTS14EM form a group. In total, a maximum of 50 FTS14EMs with 500 buttons or contacts are possible in an RS485 bus. In order to generate the necessary learning telegrams for teaching into the actuators, the desired group must be selected on the upper and lower rotary switches. For buttons in the UT or RT range or for window/door contacts and motion detectors in the RT range. Then press the desired control input. During operation, the same group must then be selected in the area UT or RT for buttons or UT for window/door contacts and motion sensors. The LED under the upper rotary switch flashes briefly when a connected contact is closed. Optional: A FAM14 radio antenna module from the building radio system, which is only two division units wide, can also be installed, which means that the actuators can then be controlled by radio buttons, hand transmitters and radio sensors via the FTS14EM in addition to the conventional buttons and contacts. Since the FAM14 has an integrated switching power supply, the FTS14KS is not required for power supply in this installation. The bidirectional FAM14 also makes it possible to evaluate feedback from the actuators via radio from the SafeIV smart home center. The respective status of the actuators can be displayed and also changed. Connecting the HOLD terminals of all devices controls bus access and prevents collisions. With the optional radio output module FTS14FA, the telegrams from the FTS14EM can also be sent to the Eltako building radio.
... more
Bus system KNX no
Bus system KNX radio no
Bus system radio bus yes
Bus system LON no
Bus system Powernet no
Other bus systems other
Radio bidirectional yes
Mounting REG
Width in division units 2
Number of activation points 10
Mounting Clamp
IP protection) IP20

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "Pushbutton input module for RS485 bus FTS14EM"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.