Installation contactor iCT, 40A, 3P+N, 4-NC A9C22740

Schneider Electric - A9C22740 - Installation contactor iCT, 40A, 3P+N, 4-NC A9C22740
Photo source: fig. possibly similar
A9C22740 3606489737153 EAN/GTIN DE 33842582 WEEE

¥766.86 excl. VAT
¥1,511.62 (-49.27% RRP***)

15-16 days* (CHN)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Installation contactor 230...240VAC, Installation contactor 230...240VAC Rated operating voltage... more
Installation contactor iCT, 40A, 3P+N, 4-NC A9C22740 – Schneider Electric – 3606489737153: Installation contactor 230...240VAC, Installation contactor 230...240VAC Rated operating voltage 220 ... 240V, Rated operation current 40A, Utility category 7, Rated excitation voltage 230 ... 240V, Voltage type (operating voltage) AC, Voltage type (excitation voltage) AC, Number of contacts as normally open contact 0, Number of contacts as normally closed contact 4, Max. incandescent lamp load 15750W, Max. load fluorescent lamp 7200VA, Max. load fluorescent lamp (Duo circuit) 11400VA, Max. load fluorescent lamp (parallel compensated) 7200VA, Number of modular spacings 3, Built-in depth 43,5mm, Additional equipment possible, Degree of protection (IP) IP20
... more
Rated operating voltage 220..240 V
Rated operating current 40 A
Utilization category 7
Rated control voltage 230..240 V
Voltage type of the operating voltage AC
Voltage type of the actuating voltage AC
Number of contacts as opener 4
Max. Incandescent lamp load 354 V
Max. Fluorescent lamp load 7200 VA
Slider for manual operation no
Width in division units 3
Depth 43.5 mm
Additional equipment possible yes
IP protection) IP20