Surge protection device for 4 signal wires PT-IQ-4X1-24DC-PT

Phoenix - PT-IQ-4X1-24DC-PT - Surge protection device for 4 signal wires PT-IQ-4X1-24DC-PT
Photo source: fig. possibly similar
Photo source: fig. possibly similar
PT-IQ-4X1-24DC-PT 2801271 4046356766531 EAN/GTIN DE 50738265 WEEE

¥1,344.03 excl. VAT
¥2,562.96 (-47.56% RRP***)

15-16 days* (CHN)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Surge protection device for 4 signal wires PT-IQ-4X1-24DC-PT Rated voltage DC 24 ... 24V, maximum... more
Surge protection device for 4 signal wires PT-IQ-4X1-24DC-PT – Phoenix – 2801271 – 4046356766531: Surge protection device for 4 signal wires PT-IQ-4X1-24DC-PT Rated voltage DC 24 ... 24V, maximum continuous voltage AC 21V, maximum continuous voltage DC 30V, rated discharge current (8/20) 10kA, rated load current 0.7A, protection level wire/earth 55V, limit frequency 1.1MHz, other type of installation, connection 1 terminal, arrester monitoring, optical signaling on the device, overvoltage protection, consisting of protective plug and base element, with integrated multi-stage status display on the module for four signal wires with a common reference potential.
... more
Rated voltage DC 24V
Highest continuous voltage AC 21V
Highest continuous voltage DC 30 V
Nominal discharge current (8/20) 10 kA
Nominal load current 0.7 A
Protection level core / earth 55V
Cut-off frequency 1.1 MHz
Mounting other
Connection 1 Clamp
SPD yes
With telecommunication contact no
Signaling on the device optical
Explosion-tested version no

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "Surge protection device for 4 signal wires PT-IQ-4X1-24DC-PT"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.