Lightning arrester for signal systems KAZ 12

KAZ 12 21810002 4021121450785 EAN/GTIN DE 66199153 WEEE

Our best price
¥268.97 excl. VAT

15-16 days* (CHN)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Lightning arrester KAZ 12 rated voltage DC 60V, maximum continuous voltage DC 60V, rated... more
Lightning arrester for signal systems KAZ 12 – Kathrein – 21810002 – 4021121450785: Lightning arrester KAZ 12 rated voltage DC 60V, maximum continuous voltage DC 60V, rated discharge current (8/20) 10kA, rated load current 2A, protection level 700V, signaling on the device without, type of installation other, connection 1 F connector, to protect the system components in SAT, BK and DVB-T receiving and distribution systems. By using the KAZ 12, the current discharge capacity of the KAZ 11 is increased. Can be used according to the lightning protection zone concept at the interfaces LPZ 0A-1 and higher. Fulfills category A2/C2/C3/B2/D1 according to EN 61643-21
... more
Rated voltage AC 0 V
Rated voltage DC 60V
Highest continuous voltage AC 700V
Highest continuous voltage DC 700V
Lightning impulse current (10/350 µs) 2.5 kA
Nominal discharge current (8/20) 10 kA
Nominal load current 2 A
Protection level 700V
Protection level wire / core 600V
Protection level core / earth 600V
Protection level wire / signal ground 700V
Protection level Signalground / Protectiveground 600V
Frequency 5..2400 MHz
Cut-off frequency 2450 MHz
Signaling on the device without
Mounting other
SPD no
Connection 1 F-connector
With telecommunication contact no
Explosion-tested version no

Rate item