Surge arrester SPD type 1+2, 3-phase. - Combined arrester for power systems 7P.05.8.260.1025

Finder - 7P.05.8.260.1025 - Surge arrester SPD type 1+2, 3-phase. - Combined arrester for power systems 7P.05.8.260.1025
Photo source: fig. possibly similar
Photo source: fig. possibly similar
7P.05.8.260.1025 8012823350226 EAN/GTIN DE 43501029 WEEE

¥4,290.45 excl. VAT
¥8,007.50 (-46.42% RRP***)

15-16 days* (CHN)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Combined arrester for power systems, System configuration DC no, System configuration IT no,... more
Surge arrester SPD type 1+2, 3-phase. - Combined arrester for power systems 7P.05.8.260.1025 – Finder – 8012823350226: Combined arrester for power systems, System configuration DC no, System configuration IT no, System configuration TN no, System configuration TN-C no, System configuration TN-CS no, System configuration TN-S yes, System configuration TT no, System configuration other no, Number of poles 4, Lightning impulse current (10/350 µs) 25 kA, Highest continuous voltage AC 260 V, Rated voltage AC 230V, Protection level 1.5 kV, Follow current extinguishing capability 0 kA, Mounting DIN rail TH35, Size 8 TE, Remote signaling yes, Signaling on the device optical, Test class Type 1 and 2, Extinguishing no, Integrated back-up fuse no, Degree of protection (IP) IP20
... more
Network form DC no
Network form IT no
Network shape TN no
Mains form TN-C no
Mains form TN-CS no
Mains form TN-S yes
Network shape TT no
Network form other no
Number of poles 4
Lightning impulse current (10/350 µs) 25 kA
Highest continuous voltage AC 260 V
Rated voltage AC 230V
Protection level 1.5 kV
Follow current extinguishing capability 0 kA
Mounting DIN rail TH35
Size 8 TE
Remote signaling yes
Signaling on the device optical
Test class Type 1 and 2
Integrated backup fuse no
Voltage switching spark gap technology yes
Overcurrent-protected voltage tap-off no
IP protection) IP20