Voltage measuring relay UC 24-230V 5A - Voltage monitoring relay 0,2...60V AC/DC MRUL

Eberle - MRUL - Voltage measuring relay UC 24-230V 5A - Voltage monitoring relay 0,2...60V AC/DC MRUL
Photo source: fig. possibly similar
Photo source: fig. possibly similar
MRUL 040010740300 4017254148736 EAN/GTIN DE 59919971 WEEE

Our best price
¥799.78 excl. VAT
¥1,154.11 (-30.7% RRP***)

15-16 days* (CHN)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Voltage monitoring relay 0,2...60V AC/DC, Voltage monitoring relay 0,2...60V AC/DC Type of... more
Voltage measuring relay UC 24-230V 5A - Voltage monitoring relay 0,2...60V AC/DC MRUL – Eberle – 040010740300 – 4017254148736: Voltage monitoring relay 0,2...60V AC/DC, Voltage monitoring relay 0,2...60V AC/DC Type of electric connection Screw connection, Single-phase under voltage possible, Single-phase over voltage possible, Contains function DC-under voltage, Contains function DC-over voltage, Voltage measurement range 1 0,2 ... 60V, Type of voltage measurement range AC/DC, Rated control supply voltage Us at AC 50HZ 24 ... 240V, Rated control supply voltage Us at AC 60HZ 24 ... 240V, Rated control supply voltage Us at DC 24 ... 240V, Voltage type for actuating AC/DC, Min. adjustable delay-on energization time 0,1s, Max. permitted delay-on energization time 3s, Number of contacts as change-over contact 2, Width 35mm, Height 90mm, Depth 63,5mm
... more
With removable clamps no
1-phase undervoltage possible yes
3-phase undervoltage possible no
1-phase overvoltage possible yes
3-phase overvoltage possible no
1-phase window possible no
3-phase window possible no
Contains function DC voltage undervoltage yes
Contains function DC voltage overvoltage yes
Contains function DC voltage window no
Voltage measuring range 1 0,2..60 V
Voltage type of the measuring range AC/DC
Voltage type for actuation AC/DC
Minimum adjustable response delay time 0.1 s
Max. Allowable response delay time 3 s
Number of contacts as changer 2
Width 35 mm
Height 90 mm
Depth 63.5 mm