Contact element 1NC, front - Auxiliary contact block 0 NO/1 NC M22-K01

M22-K01 216378 4015082163785 EAN/GTIN DE 92318050 WEEE

Our best price
¥29.27 excl. VAT
¥50.49 (-42.03% RRP***)

4-5 days* (CHN)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Contact element 1Ö, front M22-K01 Number of contacts as changeover contacts 0, number of contacts... more
Contact element 1NC, front - Auxiliary contact block 0 NO/1 NC M22-K01 – Eaton – 216378 – 4015082163785: Contact element 1Ö, front M22-K01 Number of contacts as changeover contacts 0, number of contacts as make contacts 0, number of contacts as break contacts 1, number of error signal switches 0, rated operating current Ie at AC-15, 230 V 6A, design of the electrical connection screw connection, Design can be plugged on and integrated, mounting type: front mounting, socket without, contact element, standard/approval: UL/CSA, IEC, size: NZM1/2/3/4, connection technology: screw terminals, mounting: front mounting, contact assembly NC = NC: 1 NC, contact assembly Note: = Safety function, through positive opening according to IEC/EN 60947-5-1, travel of the control panel and actuation force according to DIN EN 60947-5-1, K.5.4.1 positive opening travel: mm 4.8, maximum travel: mm 5.7, minimum force for positive opening : N 15, Protection class: IP20, Connection to SmartWire-DT: no, Connection type: Single contact, Description of tripped auxiliary switch HIA: General tripped message “+” when tripped by voltage release, overload release, short-circuit release and when using the residual current release due to residual current., Use with circuit breaker size NZM1, 2, 3: One tripped auxiliary switch can be clipped into the circuit breaker., Use with circuit breaker size NZM4: Up to two tripped auxiliary switches can be clipped into the circuit breaker., Any combination of auxiliary switch types are possible., Not in conjunction with switch disconnector PN…, Marking in Switch: HIA., Identification in the FI block: HIAFI., When using the tripped auxiliary switches in the FI block, the normally closed contact works as a normally open contact and the normally open contact works as a normally closed contact., Description Normal auxiliary switch HIN: Switches with the main contacts. Takes on signaling and interlocking tasks., Use with circuit breaker size NZM1: A normal auxiliary switch can be clipped into the circuit breaker., Use with circuit breaker size NZM2: Up to two normal auxiliary switches can be clipped into the circuit breaker., Use with circuit breaker size NZM3, 4: Up to three Normal auxiliary switches can be clipped into the circuit breaker., Any combination of auxiliary switch types are possible., Marking in the switch: HIN., When combined with remote drive NZM-XR..., the right-hand installation slot for normal auxiliary switch HIN can only be equipped with individual contacts., Can be used for: NZM1( -4), 2(-4), 3(-4), 4(-4), PN1(-4), 2(-4), 3(-4), N(S)1(-4), 2(-4), 3(-4), 4(-4), standards and regulations: IEC 60947-5-1
... more
Number of contacts as opener 1
Rated operational current Ie at AC-15, 230 V 6A
Execution attachable and integrable
Mounting Front fixing
Version without

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "Contact element 1NC, front - Auxiliary contact block 0 NO/1 NC M22-K01"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.