RCD combination/RCBO - Earth leakage circuit breaker DRCBO3B32/0,03/1NAKV

Doepke - DRCBO3B32/0,03/1NAKV - RCD combination/RCBO - Earth leakage circuit breaker DRCBO3B32/0,03/1NAKV
Photo source: fig. possibly similar
Photo source: fig. possibly similar
DRCBO3B32/0,03/1NAKV 09932407 4014712220966 EAN/GTIN DE 85624250 WEEE

¥727.56 excl. VAT
¥1,204.19 (-39.58% RRP***)

15-16 days* (CHN)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
FI/LS combination/RCBO DRCBO3B32/0.03/1NAKV number of poles (total) 2, number of fused poles 1,... more
RCD combination/RCBO - Earth leakage circuit breaker DRCBO3B32/0,03/1NAKV – Doepke – 09932407 – 4014712220966: FI/LS combination/RCBO DRCBO3B32/0.03/1NAKV number of poles (total) 2, number of fused poles 1, rated voltage 230V, rated insulation voltage Ui 440V, rated impulse withstand voltage Uimp 4kV, rated current 32A, rated residual current 0.03A, residual current type A, Energy limitation class 3, rated breaking capacity according to EN 61009 10kA, rated breaking capacity according to IEC 60947-2 10kA, rated short-circuit breaking capacity Icn according to EN 61009-1 10kA, short-time delayed switch-off characteristic, surge current strength 3kA, type of voltage AC, frequency 50 Hz, tripping characteristic B, overvoltage category 3, degree of pollution 2, ambient temperature during of operation -25 ... 40°C, width in pitch units 2, installation depth 68mm, degree of protection (IP) IP20, connectable conductor cross-section solid 1 ... 25mm², connectable conductor cross-section stranded 1 ... 25mm², RCBO combine residual current and miniature circuit breakers in a device (FI/LS combination). They protect people from fault currents and systems from short circuits and overloads. The switches of the DRCBO 3 series work independently of the mains voltage and are characterized by a high rated switching capacity. Separate displays enable a quick overview of the current operating status. DRCBO 3 can be easily installed and removed. Type A switches are pulse and AC sensitive. This function is independent of the mains voltage. Switches with tripping characteristic B are the standard protection for light and socket circuits. Switches in the KV version have a response delay and are therefore considerably less sensitive to short-term pulsed fault currents. This increases system availability. In principle, they can be used instead of a standard switch, since their protective function is fully retained. Properties: Tripping independent of auxiliary voltage, sensitive to AC and pulsating DC residual currents (type A), small size for all rated currents, high short-circuit strength, green-red contact position indicator, residual current trip indicator, clamping yoke terminals with protection from behind and wide terminal cross-section range for rail and cable wiring on both connection sides, neutral conductor on the right, tristable latching slide for easy installation and removal, type of installation: quick fastening on DIN rail, any installation position, any supply, areas of application: protection of circuits in residential and commercial buildings as well as industrial plants with TN-S and TN-CS networks. In IT networks, RCBOs can be provided to switch off in the event of a second earth fault. Use in systems with TN-C networks and to protect circuits is excluded. in which power electronics equipment can cause smooth DC fault currents or fault currents with frequencies not equal to 50/60 Hz.
... more
Number of poles (total) 2
Number of secured poles 1
Rated voltage 230V
Rated insulation voltage Ui 440V
Rated impulse withstand voltage Uimp 4 kV
Rated current 32 A
Rated fault current 0,02999999 A
Fault current type A
Limiting class 3
Rated breaking capacity according to EN 61009 10 kA
turn-off characteristic time-delayed
Surge current resistance 3 kA
Voltage AC
Frequency 50 Hz
Release characteristic B
Coupling neutral conductor yes
With locking device yes
Overvoltage category 3
Pollution degree 2
Width in division units 2
Depth 68 mm
Flush mounting no
False triggering protection no
IP protection) IP20