Surge arrester DEHNrapid LSA protective plug - Surge protection for signal systems DRL PD 180

DRL PD 180 907430 4013364107670 EAN/GTIN DE 11890845 WEEE

Our best price
¥172.94 excl. VAT
¥327.52 (-47.2% RRP***)

4-5 days* (CHN)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
ÜS arrester DEHNrapid LSA protective plug DRL PD 180 Rated voltage DC 180 ... 180V, maximum... more
Surge arrester DEHNrapid LSA protective plug - Surge protection for signal systems DRL PD 180 – Dehn – 907430 – 4013364107670: ÜS arrester DEHNrapid LSA protective plug DRL PD 180 Rated voltage DC 180 ... 180V, maximum continuous voltage AC 127V, maximum continuous voltage DC 180V, rated discharge current (8/20) 10kA, lightning impulse current (10/350 µs) 5kA, rated load current 0.1A, protection level Wire/wire 270V, protection level wire/earth 500V, limit frequency 61MHz, installation type LSA-Plus pluggable, connection 1 other, protective plug 1 DA energetically coordinated with DRL plug-in magazine as one-stage end device protection. Low protection level wire-wire and integrated overcurrent protection for ADSL, ISDN Uk0 or a/b wires. Mounting with EF 10 DRL. Installation only recommended in connection with the DRL plug-in magazine.
... more
Rated voltage DC 180V
Highest continuous voltage AC 127 V
Highest continuous voltage DC 180V
Nominal discharge current (8/20) 10 kA
Lightning impulse current (10/350 µs) 5 kA
Nominal load current 0.1 A
Protection level wire / core 270 V
Protection level core / earth 500V
Cut-off frequency 61 MHz
Mounting LSA-Plus pluggable
Connection 1 other
SPD no
With telecommunication contact no
Explosion-tested version no
Separation option for signal circuit no
Number of conductors (without earth) 2
Earthing via other
Overall width 9.4 mm
IP protection) IP20

Rate item