DEHNgap N-PE lightning arrester - Lightning arrest for power supply 100kA DGP M 255

DGP M 255 961101 4013364118676 EAN/GTIN DE 11890845 WEEE

Our best price
¥1,510.32 excl. VAT
¥2,860.46 (-47.2% RRP***)

15-16 days* (CHN)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
N-PE lightning current arrester DEHNgap DGP M 255 TT network type, number of conductors (without... more
DEHNgap N-PE lightning arrester - Lightning arrest for power supply 100kA DGP M 255 – Dehn – 961101 – 4013364118676: N-PE lightning current arrester DEHNgap DGP M 255 TT network type, number of conductors (without earth) 1, lightning impulse current (10/350 µs) 100kA, nominal discharge current (8/20) 100kA, maximum continuous voltage AC 255V, nominal voltage AC 230V, protection level 1, 5kV, protection level N-PE 1.5kV, follow current extinguishing capability 0.1kA, specific energy (W/R) 2500kJ/Ohm, mounting type DIN rail TH35, size 2 TE, max. conductor cross-section solid (single/stranded) 50mm², max (finely stranded) 35mm², optical signaling on the device, test class type 1, degree of protection (IP) IP20, single-pole, coordinated N-PE lightning current arrester DEHNgap modular, type 1 according to EN 61643-11. Summation current arrester especially for use in the TT system in the 3+1 and 1+1 circuit according to DIN VDE 0100-534 between N and PE. To protect low-voltage consumer systems against overvoltages, even in the event of direct lightning strikes. For use in the lightning protection zone concept at the interfaces 0A - 1 in the 3+1 circuit variant.
... more
Network form DC no
Network form IT no
Network shape TN no
Mains form TN-C no
Mains form TN-CS no
Mains form TN-S no
Network shape TT yes
Network form other no
Number of conductors (without earth) 1
Lightning impulse current (10/350 µs) 100 kA
Nominal discharge current (8/20) 100 kA
Highest continuous voltage AC 255V
Rated voltage AC 230V
Protection level 1.5 kV
Protection level N-PE 1.5 kV
Follow current extinguishing capability 0.1 kA
Specific energy (W / R) 2500 kJ/ohm
Mounting DIN rail TH35
Size 2 TE
With telecommunication contact no
Blow out no
Signaling on the device optical
Test class type 1 yes
Integrated backup fuse no
Suitable for outdoor use no
IP protection) IP20