Blitzductor XT combined arrester - Combined arrester for signal systems BXT ML2 BE S 36

Dehn - BXT ML2 BE S 36 - Blitzductor XT combined arrester - Combined arrester for signal systems BXT ML2 BE S 36
Photo source: fig. possibly similar
Photo source: fig. possibly similar
BXT ML2 BE S 36 920226 4013364142121 EAN/GTIN DE 11890845 WEEE

Our best price
¥954.83 excl. VAT
¥1,808.45 (-47.2% RRP***)

15-16 days* (CHN)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Combination arrester Blitzductor XT BXT ML2 BE S 36 Rated voltage DC 36 ... 36V, maximum... more
Blitzductor XT combined arrester - Combined arrester for signal systems BXT ML2 BE S 36 – Dehn – 920226 – 4013364142121: Combination arrester Blitzductor XT BXT ML2 BE S 36 Rated voltage DC 36 ... 36V, maximum continuous voltage AC 31V, maximum continuous voltage DC 45V, lightning impulse current (10/350 µs) 9kA, nominal discharge current (8/20) 20kA, nominal load current 1.8A, Protection level wire/wire 112V, protection level wire/earth 56V, limit frequency 3.8MHz, type of installation on base element, arrester monitoring, space-saving combination arrester module with LifeCheck for protecting 2 individual wires with a common reference potential and asymmetrical interfaces, optionally direct or indirect shield earthing. LifeCheck detects thermal or electrical overload conditions after which the arrester must be replaced. The display is contactless using DEHNrecord LC / SCM / MCM.
... more
Rated voltage DC 36 V
Highest continuous voltage AC 31 V
Highest continuous voltage DC 45 V
Lightning impulse current (10/350 µs) 9 kA
Nominal discharge current (8/20) 20 kA
Nominal load current 1.8 A
Protection level wire / core 112 V
Protection level core / earth 56 V
Cut-off frequency 3.8 MHz
Mounting on base element
Connection 1 Screw terminal
SPD yes
With telecommunication contact no
Explosion-tested version no
Separation option for signal circuit no
Number of conductors (without earth) 2
Earthing via DIN rail
Overall width 12 mm
IP protection) IP20