Residual current circuit breaker per M Compact F202A-16/0,01

F202A-16/0,01 2CSF202101R0160 8012542782407 EAN/GTIN DE 91945327 WEEE

Our best price
¥624.62 excl. VAT
¥1,211.51 (-48.44% RRP***)

4-5 days* (CHN)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
FI circuit breaker per M Compact F202A-16/0.01 number of poles 2, rated voltage 230V, rated... more
Residual current circuit breaker per M Compact F202A-16/0,01 – ABB – 2CSF202101R0160 – 8012542782407: FI circuit breaker per M Compact F202A-16/0.01 number of poles 2, rated voltage 230V, rated current 16A, rated residual current 0.01mA, rated insulation voltage Ui 500V, rated impulse withstand voltage Uimp 4kV, mounting type DIN rail, residual current type A, short-circuit strength (Icw) 1kA , surge current strength 0.3kA, frequency 50/60 Hz, additional equipment possible, with locking device, degree of protection (IP) IP2X, width in modular widths 2, installation depth 69mm, ambient temperature during operation -25 ... 55°C, degree of pollution 2, connectable conductor cross-section stranded 0 ... 25mm², connectable conductor cross-section solid 25 ... 25mm², residual current protective devices (RCCBs) offer personal and property protection as well as protection against electrically ignited fires in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. The residual current circuit breakers of the F200 series ensure protection against sinusoidal alternating currents and pulsating currents with a smooth DC residual current component of up to 6 mA to earth. As well as fault protection (protection against indirect contact), additional protection (with I?n = 30 mA) and fire protection (with I?n = 300 mA). They meet the product standards IEC/EN 61008-1, 61008-2-1, 61543 (VDE 0664 10, 11, 30) and for F200 A to 100 A UL 1053. Areas of application are household, commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the F200 fit for worldwide use.
... more
Number of poles 2
Rated voltage 230V
Rated current 16 A
Rated fault current 0.01A
Rated insulation voltage Ui 500V
Rated impulse withstand voltage Uimp 4 kV
Mounting DIN rail
Fault current type A
Selective type no
Short time delayed type no
Short-circuit strength (Icw) 1 kA
Surge current resistance 0.25 kA
Voltage AC
With locking device yes
Frequency other
Additional equipment possible yes
IP protection) IP2X
Width in division units 2
Depth 69 mm
Pollution degree 2
Explosion protection no

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "Residual current circuit breaker per M Compact F202A-16/0,01"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.