Fuse switch 160A - NH000, NH00-Fuse switch disconnector XLP00-A40/75-3BC

ABB - XLP00-A40/75-3BC - Fuse switch 160A - NH000, NH00-Fuse switch disconnector XLP00-A40/75-3BC
Photo source: fig. possibly similar
Photo source: fig. possibly similar
XLP00-A40/75-3BC 1SEP101898R0002 7025840016403 EAN/GTIN DE 91945327 WEEE

¥866.47 excl. VAT
¥1,551.15 (-44.14% RRP***)

15-16 days* (CHN)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Fuse switch disconnector 160A XLP00-A40/75-3BC design as a main switch, design as a safety... more
Fuse switch 160A - NH000, NH00-Fuse switch disconnector XLP00-A40/75-3BC – ABB – 1SEP101898R0002 – 7025840016403: Fuse switch disconnector 160A XLP00-A40/75-3BC design as a main switch, design as a safety switch, max. rated operating voltage Ue at AC 690V, rated uninterrupted current Iu 125A, conditional rated short-circuit current Iq 50kA, suitable for fuse links NH000, NH00, number of poles 3, connection type main circuit cable clamp , Other cable entry, Equipped with connectors, Suitable for busbar assembly, Other operating element design, Front operating element position, Degree of protection (IP), IP30 on the front, The EasyLine series from ABB has a robust, uniform design that is user-friendly. Thanks to this modern design, the series switches rated currents from 100 A - 630 A at voltages from 220 V to 690 V with ease. In addition, a high level of safety is guaranteed with protection class IP30 from the front in the closed position and protection class IP20 in the open position. ABB offers you the series in 1, 2, 3 and 4-pole variants including a wide range of cable clamps and snap-on accessories. In addition, the devices are tested according to EN / IEC 60947-3.
... more
Version as main switch yes
Version as safety switch yes
Max. Rated operating voltage Ue at AC 690V
Rated continuous current Iu 125 A
Conditional rated short-circuit current Iq 50 kA
Suitable for fuse links NH000, NH00
Number of poles 3
With fuse monitoring no
Connection type main circuit Cable clamp
Cable entry other
Equipped with connectors yes
Suitable for ground mounting no
Suitable for front attachment no
Suitable for busbar construction yes
Execution of the actuating element other
Position of the actuator ahead
Motor drive optional no
Motor drive integrated no
Version as emergency stop device no
Degree of protection (IP), front side IP30

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "Fuse switch 160A - NH000, NH00-Fuse switch disconnector XLP00-A40/75-3BC"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.